90° Infrared Light Scattering Turbidity Sensor for Water Quality Analysis

ʻO ka wehewehe pōkole:

Hoʻohana ka Turbidity Sensor i ka 90° infrared light scattering principle e hāʻawi i nā ana pololei i nā kaiapuni koi. Hoʻolālā ʻia no ka mālama ʻana i ka wai ʻino, ka nānā ʻana i ke kaiapuni, a me nā kaʻina hana ʻoihana, hōʻike ia i ke kūpaʻa maikaʻi loa i ka hoʻopili ʻana i nā kukui ambient ma o nā ala kukui fiber-optic kiʻekiʻe, nā ʻenehana polishing kūikawā, a me nā polokalamu algorithms. Me ka liʻiliʻi liʻiliʻi a me kahi hoʻolālā kūpono o ka lā, hana pono ia ma waho a i ʻole i ka lā pololei. Pono ka hana paʻa i 30 mL wale nō o ka hopena maʻamau no ka calibration a loaʻa kahi koi haʻahaʻa kokoke (<5 cm) i nā mea pale. Kūkulu ʻia me 316L stainless steel a hāʻawi i ka RS-485 MODBUS output, e hōʻoia kēia sensor i ka paʻa a me ka pololei i nā kūlana paʻakikī.


Huahana Huahana

Huahana Huahana

Nā hiʻohiʻona

① 90° ʻenehana Hoʻopuehu Infrared

Hoʻopili i nā kūlana ʻenehana optical, hōʻoia ka sensor i nā ana turbidity kiʻekiʻe ma o ka hoʻemi ʻana i ka chromaticity interference a me nā hopena māmā ambient.

② Hoʻolālā Kūleʻa Lā

ʻO nā ala māmā fiber-optic kiʻekiʻe a me nā algorithms uku pānaʻi e hiki ai i ka hana paʻa ma lalo o ka lā pololei, kūpono no nā hoʻonohonoho waho a i ʻole ka lewa.

③ Māmā a haʻahaʻa

Me kahi koi kokoke <5 knm i nā pilikia a me ka liʻiliʻi o ka calibration volume (30 mL), hoʻomaʻamaʻa ia i ka hoʻohui ʻana i loko o nā pahu, nā paipu, a i ʻole nā ​​​​pūnaewele lawe lima.

④ Hana ʻAi-Corrosion

ʻO ka hale 316L stainless steel e kū'ē i nā kaiapuni kemika koʻikoʻi, e hōʻoia ana i ka hilinaʻi lōʻihi ma nāʻoihanaʻoihana a iʻole ka moana.

⑤ Hana ʻole Drift-Free

ʻO nā algorithms software proprietary a me nā optics pololei e hōʻemi i ka neʻe ʻana o ka hōʻailona, ​​​​e hōʻoiaʻiʻo ana i ka pololei ma waena o nā kūlana fluctuating.

16
15

Nā Kūlana Huahana

Inoa Huahana ʻIke ʻeleu
ʻAno ana 90 ° ke ala hoʻopuʻi māmā
Laulā 0-100NTU/ 0-3000NTU
Ka pololei Ma lalo o ± 10% o ka waiwai i ana ʻia (ma muli o ka homogeneity sludge) a i ʻole 10mg/L, ʻoi aku ka nui.
Ka mana 9-24VDC(Manaʻo 12 VDC)
Nui 50mm*200mm
Mea waiwai 316L kila kila
Hoʻopuka RS-485, kaʻina MODBUS

Palapala noi

1. Nā mea kanu hoʻomaʻemaʻe wai ʻino

E nānā i ka turbidity i ka manawa maoli e hoʻonui i ka kānana, sedimentation, a me ka hoʻokuʻu ʻana.

2. Nānā Kaiapuni

E hoʻolālā i nā kahawai, nā loko, a i ʻole nā ​​​​waiwai e nānā i nā pae sediment a me nā hanana haumia.

3. Pūnaehana Wai inu

E hōʻoia i ka maopopo o ka wai ma o ka ʻike ʻana i nā ʻāpana i hoʻokuʻu ʻia i nā keʻena lapaʻau a i ʻole nā ​​​​pūnaewele hoʻolaha.

4. Hooponopono I'a

E mālama i ka maikaʻi o ka wai no ke olakino wai ma o ka pale ʻana i ka turbidity nui.

5. Ka Mana Hana Hana Hana

Hoʻohui i loko o nā kaʻina hana kemika a lāʻau lapaʻau paha e hōʻoia i ka maikaʻi o ka huahana a me ka hoʻoponopono hoʻoponopono.

6. Mining & Construction

Mākaʻikaʻi i ka huʻihuʻi wai e hoʻokō i nā lula kaiapuni a me ka hoʻēmi ʻana i nā pilikia o ka haumia pili i ka sediment ma nā kaiaola a puni.

7. Noi'i & Keena Hana

Kākoʻo i nā haʻawina ʻepekema e pili ana i ka mālamalama o ka wai, ka ikaika o ka sediment, a me ka hoʻohālike pollution me ka ʻikepili turbidity kiʻekiʻe.

DO PH Temperatur Sensors O2 Meter Dissolved Oxygen PH Analyzer Application

  • Mua:
  • Aʻe: