Kikokikona koena Chlorine Sensor no ka nana pono wai

ʻO ka wehewehe pōkole:

Ke hoʻohana nei kēia mea ʻike kiʻekiʻe kiʻekiʻe o ka chlorine i kahi hoʻolālā hoʻolālā mau ʻekolu-electrode e hāʻawi i nā ana manawa maoli o ka chlorine manuahi (ClO⁻/HClO) i nā ʻōnaehana wai. Me ka laulā ana ākea (0-20.00 ppm) a me nā ʻōlelo hoʻoholo i lalo i ka 0.001 ppm, e hōʻoiaʻiʻo ia i ka nānā pono ʻana no ka palekana wai inu, ka hoʻokō pono ʻana i ka ʻoihana, a me ka hoʻokele iʻa. Hoʻohui ka mea ʻike i ka uku pH e hōʻemi i ke ana drift a kākoʻo iā Modbus RTU ma luna o RS485 no ka hoʻohui pono ʻana i ka SCADA, IoT, a i ʻole nā ​​​​pūnaehana mana ʻoihana. Hoʻopili ʻia i loko o kahi hale paʻa, IP68-helu ʻia me nā koho thread G3/4, hāʻawi ia i ka hoʻonohonoho maʻalahi i nā kaiapuni kahe a i ʻole i lalo. ʻO nā kauoha calibration aunoa a me kahi uhi electrode hoʻomaʻemaʻe ponoʻī koho e hōʻoia i ka paʻa lōʻihi a me ka mālama ʻana.


Huahana Huahana

Huahana Huahana

Nā hiʻohiʻona

① ʻEkolu-Electrode mau ʻenehana hikiwawe

E hōʻoia i nā ana kūpaʻa ma o ka hoʻemi ʻana i nā hopena polarization a me ka hoʻopilikia ʻana mai ka piʻi ʻana o ka pH, ʻoiai i nā kūlana wai ikaika.

② Hoʻoholo i nā pae he nui a me ka uku pH

Kākoʻo i nā ʻōlelo hoʻoholo mai ka 0.001 ppm a i ka 0.1 ppm a me ka uku pH maʻalahi e hoʻomaikaʻi i ka pololei i nā ʻano kemika wai.

③ Hoʻohui RTU Modbus

Hoʻonohonoho mua ʻia me ka helu helu paʻamau (0x01) a me ka helu baud (9600 N81), hiki i ka hoʻopili plug-a-pāʻani i nā ʻōnaehana automation ʻoihana.

④ Hoʻolālā Paʻa no nā Kaiapuni Paʻakikī

ʻO ka hale i helu ʻia IP68 a me nā electrodes pale i ka corrosion e kū i ka hoʻohaʻahaʻa lōʻihi, nā kahe kiʻekiʻe, a me nā mahana a hiki i 60 ℃.

⑤ Hoʻoponopono Haʻahaʻa & Hoʻopaʻa ʻana iā ia iho

Loaʻa i nā kauoha calibration zero/slope ʻakomi, pane kuhi hewa, a me nā uhi pale koho e hōʻemi i ka biofouling a me ka mālama lima.

8
7

Nā Kūlana Huahana

Inoa Huahana Koena Klorine Sensor
Hoʻohālike LMS-HCLO100
Laulā Meka chlorine koena: 0 - 20.00 ppm Mahana: 0- 50.0 ℃
Ka pololei ʻO ka mika chlorine koena: ± 5.0% FS, kākoʻo i ka hana uku pH Ka Mahana: ± 0.5 ℃
Ka mana 6VDC-30VDC
Mea waiwai Polimer Pīlaki
Manawa hoʻohiki ʻO ke poʻo uila 12 mahina/papa kikohoʻe 12 mahina
Kākoʻo ʻia ka mea ʻike RS-485, kaʻina MODBUS
Ka lōʻihi o ke kaula 5m, hiki ke hoʻonui ʻia e like me ka pono o ka mea hoʻohana
Palapala noi ʻO ka mālama ʻana i ka wai, ka nānā ʻana i ka maikaʻi o ka wai ʻauʻau, a me ka mālama ʻana i ka wai ʻino.

 

Palapala noi

1. Lapaau wai inu

E nānā i ke koena o ka chlorine pae i ka manawa maoli e hōʻoia i ka disinfection efficacy a me ka hoʻokō kānāwai.

2. Hoʻoponopono Wai ʻino ʻOihana

E hahai i ka chlorine i loko o nā effluents e hoʻokō i nā kūlana hoʻokuʻu kaiapuni a pale i nā hoʻopaʻi.

3. Pūnaehana Aquaculture

Kāohi i ka over-chlorination i loko o nā mahiʻai iʻa no ka pale ʻana i ke ola wai a hoʻomaikaʻi i ka maikaʻi o ka wai.

4. ʻAʻau ʻauʻau & Palekana Spa

E mālama i nā pae chlorine palekana no ke olakino lehulehu me ka pale ʻana i ka corrosive over-dosing.

5. Uena Waiwai Kulanakauhale akamai

E hoʻohui i nā ʻōnaehana nānā pono wai e pili ana i IoT no ka hoʻokele waiwai o ke kūlanakauhale.

DO PH Temperatur Sensors O2 Meter Dissolved Oxygen PH Analyzer Application

  • Mua:
  • Aʻe: