RIV Series Acoustic Doppler Current Profiler(ADCP)

vas (1)

With our advanced IOA broadband technology, the RIV Series ADCP is ideally used for collecting highly accurate and reliable current velocity even in harsh water environments.

Frankstar ADCP offers seamless integration with existing popular devices such as Gyro, GPS, radio station. The survey vessels and triple-hulled vessels for moving measurements are also available on demand. With our ADCPs, you can spend less time on manual tasks and more time on valuable analysis.

269133aa-d7e8-4a17-8613-ca9496b63de9

Features:

IOA broadband technology brings accurate profiling flow data

Easy maintenance with robust and reliable internal framework;

Measurement results can be uploaded to the specified Web server.

5dde5e7a-f8b1-4ae5-b95a-9b2dfd56aa29

Specification

Model RIV 1200 RIV 600 RIV 300
Current Profiling
Profiling range 0.1~40m 0.4~80m 1~120 m
Velocity range ±20m/s (default) ±20m/s (default) ±20m/s (default)
Accuracy ± 0.25% ± 2mm/s ±0.25%±2mm/s ±0.5%±5mm/s
Resolution 1mm/s 1mm/s 1mm/s
Layers Size 0.02~2m 0.25~4m 1~8m
Number of layers 1~260 1~260 1~260
Update rate 1Hz 1Hz 1Hz
Bottom tracking
Frequency 1200kHz 600kHz 300kHz
Depth range 0.1~55m 0.8~120m 2~200m
Accuracy ± 0.25% ± 2mm/s ±0.25%±2mm/s ±0.5%±5mm/s
Velocity range ±20m/s ±20m/s ±20 m/s
Update rate 1Hz 1Hz 1Hz
Transducer and hardware
Type Piston Piston Piston
Mode Broadband Broadband Broadband
Beam angle
Beam inclination 20° 20° 20°
Configuration 4 beams, JANUS 4 beams, JANUS 4 beams, JANUS
Sensor
Temperature Range: – 10°C ~ 85°C; Accuracy: ± 0.5°C; Resolution: 0.01°C Range: – 10°C ~ 85°C; Accuracy: ± 0.5°C; Resolution: 0.01°C Range: – 10°C ~ 85°C; Accuracy: ± 0.5°C; Resolution: 0.01°C
Motion  Range: ± 50°; Accuracy: ± 0.2°; Resolution: 0.01°  Range: ± 50°; Accuracy: ± 0.2°; Resolution: 0.01°  Range: ± 50°; Accuracy: ± 0.2°; Resolution: 0.01°
Heading  Range: 0~360°; Accuracy: ±0.5°(calibrated); Resolution: 0. 1°  Range: 0~360°; Accuracy: ±0.5°(calibrated); Resolution: 0. 1°  Range: 0~360°; Accuracy: ±0.5°(calibrated); Resolution: 0. 1°
Power supply and communication
Power consumption 0.5-3W 0.5-3W 0.5W-3.5W
DC input 10.5V~36V 10.5V~36V 10.5V~36V
Communications RS422, RS232 or 10M Ethernet RS422, RS232 or 10M Ethernet RS422, RS232 or 10M Ethernet
Storage 2G (extendable) 2G (extendable) 2G (extendable)
House material POM (standard), titanium, aluminium optional (depends on the depth rating required) POM (standard), titanium, aluminium optional (depends on the depth rating required) POM (standard), titanium, aluminium optional (depends on the depth rating required)
Weight and dimension
Dimension 242mm(H)×225mm (Dia) 242mm(H)×225mm (Dia) 242mm (H)×225mm (Dia)
Weight 7.5kg in air, 5kg in water (standard) 7.5kg in air, 5kg in water (standard) 7.5kg in air, 5kg in water (standard)
Environment
Maximum depth 100m/500m/2000m/4000m/6000m 100m/500m/2000m/4000m/6000m 100m/500m/2000m/4000m/6000m
Operation temperature -5°C ~ 45°C -5°C ~ 45°C -5°C ~ 45°C
Storage temperature -25°C ~ 65°C -25°C ~ 65°C -25°C ~ 65°C
Software IOA river current measurement software with acquisition and navigation modules IOA river current measurement software with acquisition and navigation modules IOA river current measurement software with acquisition and navigation modules