Technical Specifications
| Item | FS-ADCP-001 | FS-ADCP-002 | FS-ADCP-003 |
| Acoustic (Broadband Technology) | |||
| Number of Horizontal Transducers | 2 | 2 | 2 |
| Horizontal Transducer Beam Angle | 1 . 1° | 1 . 1° | 2° |
| Number of Vertical Altitude Measurement Transducers | 1 | 1 | 1 |
| Vertical Transducer Beam Angle | 5° | 5° | 5° |
| Velocity Profile Range | 0.5~35 m | 1~120m | 1~350m |
| Velocity Accuracy | ±[0.5% of reading ±2mm/s] | ±[0.5% of reading ±2mm/s] | ±[0.5% of reading ±2mm/s] |
| Velocity Measurement Range | ±5m/s( Default ),±20m/s( Maximum ) | ||
|
Resolution |
1mm/s | 1mm/s | 1mm/s |
| Number of Velocity Measurement Cells | 1~256 | 1~256 | 1~256 |
|
Measurement Cell Size |
0.25~4m | 0.5~4m | 1~8m |
|
Discharge Accuracy |
士0.5%, the calibration and testing error compared with conventional flow measurement equipment, such as routine vessel-mounted flow measurement systems or current meters, is within 5%. |
|
Water Level Measurement Range |
0.1~20m |
| Water Level Measurement Accuracy/Resolution |
±0.1%±3mm;0.1mm |
|
Blanking Distance |
≤ 0.5m |
|
Built-in Sensors |
|
|
Temperature Sensor |
Range: -10℃ ~+85℃ ; Accuracy:±0 . 1℃ ; Resolution:0 . 001℃ |
|
Attitude Sensor |
Range:0~50° ; Accuracy:±0.2° ; Resolution:0.01° |
|
Compass Sensor |
Range:0° ~360° ; Accuracy:±0.5° ; Resolution:0.01° |
|
Pressure Sensor |
Optional Accessory: Pressure Water Level Sensor 0.1~20m |
|
Data Storage
|
2 GB non-volatile memory; data is retained in the event of power failure. |
|
Communication |
|
|
Standard Protocol |
Supports RS-232、RS-422、SDI-12 |
|
Modbus Interface Module |
Supports Modbus |
| Physical Parameters | |
|
Power Supply |
9~36V VDC, with stable operation under voltage fluctuations |
|
Power Consumption |
Sampling Power Consumption≤ 1W, Sleep Power Consumption≤ 0.1mW |
|
Housing Material |
POM (Standard) / Aluminum Alloy (Optional) / Titanium Alloy (Optional) |
|
Dimensions |
270.5mm( H )x328mm( W )x202mm( Diameter) |
|
Pressure Rating |
50m( Standard )/2000m( Optional )/6000m( Optional ), Housing Protection Rating higher than IP68。 |
|
Operating Temperature |
-5℃ ~70℃ ;-20℃ ~75℃ |
|
Function Description |
The complete system provides essential functions including configuration, calibration, protection, and early warning. It also supports viewing and playback of measured data. |